Rotary vibrators
Standard voltage :
|
220/380 V – 50 Hz
|
Rotation speed :
|
750 - 1000 – 1500 – 3000 rpm
|
Protection :
|
IP 65
|
Insulation :
|
Tropicalized class
|
Acceptable ambient temperature :
|
from – 20° C to 40° C
|
Installation recommendations :
• The vibrators can be installed in every position
• Check the flatness of the surface that will rest on the vibrating structure
• Rigid attachment of the vibrator – Fastening quality 8.8. It is advisable to use a torque spanner.
• Check the tightening after the first days of operation.
• Check the intensity of the loaded vibrator: Adjust the unbalances if the recorded values exceed those on the nameplate.