TYPE |
FREQUENCY |
CENTRIFUGAL FORCE |
AIR CONSUMPTION |
||||||
|
2 Bars |
4 Bars |
6 Bars |
2 Bars = 29 PSI |
4 Bars = 58 PSI |
6 Bars = 87 PSI |
2 Bars |
4 Bars |
6 Bars |
VRS 50 |
25 000 |
35 000 |
36 000 |
1 070 |
2 920 |
4 220 |
100 |
145 |
195 |
VRS 65 |
19 000 |
21 000 |
26 000 |
2 730 |
4 830 |
6 120 |
200 |
300 |
400 |
VRS 80 |
15 500 |
18 500 |
19 000 |
3 000 |
6 090 |
7 450 |
290 |
430 |
570 |
VRS 100 |
11 000 |
14 000 |
16 000 |
3 750 |
6 750 |
8 900 |
370 |
550 |
730 |
VRS 120 |
10 000 |
11 500 |
12 500 |
8 000 |
10 000 |
12 500 |
500 |
730 |
970 |
Data obtained on a rigid test bench using a "Kistler" three-axis dynamometer. When the vibrator is mounted on a less rigid support, the frequency and force are reduced. Data subject to modification without prior warning.
TYPE |
A |
WIDTH |
C |
D |
E |
F |
G |
H* Thread |
WEIGHT |
VRS 50 |
50 |
29 |
86 |
68 |
12 |
7 |
40 |
1/8 " |
0,240 |
VRS 65 |
65 |
37 |
113 |
90 |
16 |
9 |
50 |
1/4 " |
0,545 |
VRS 80 |
80 |
43 |
128 |
104 |
16 |
9 |
60 |
1/4 " |
0,950 |
VRS 100 |
100 |
52 |
160 |
130 |
20 |
11 |
80 |
3/8 " |
1,810 |
VRS 120 |
120 |
77 |
194 |
152 |
24 |
17 |
- |
3/8 " |
4,260 |
* Compatible NTP
Maximum temperature: 140°C (280ºF)